Axis 2 · Technique · Energy and electricity

TimeShort
ContextAlone
RiskDiscreet
GearTechnical

A circuit breaker doesn't protect your appliances. It protects your wires from fire, and the RCD protects your body. When it trips, it's telling you something: understand what before you switch it back on.

What it watches

An electric wire heats up when current flows through it. Too much current and it gets hot enough to melt its insulation and start a fire inside the wall. The breaker cuts first. It watches for two different dangers, with two mechanisms:

Reading a breaker

The rating, in amps, is printed on it: the current it lets through continuously. In France, the standard ties the rating to the size of the wire it protects (other countries have their own tables, on the same principle):

CircuitWireRating
Lighting1.5 mm²10 A (16 A allowed)
Ordinary sockets1.5 mm² or 2.5 mm²16 A or 20 A
Washing machine, dishwasher, oven2.5 mm²20 A
Hob6 mm²32 A

Never a higher rating than the wire can take. Replacing a 16 A breaker that keeps tripping with a 32 A one removes the protection: the wire will heat until something burns.

The letter in front of the rating (B, C or D) says when it cuts instantly: C for ordinary household use, B for long runs, D for motors with a hard start.

The RCD: the one that saves lives

Current that leaves by the live wire must come back by the neutral. If some is missing, it's escaping somewhere else: through a wet appliance, a damaged wire, or a person. The residual current device (RCD) compares the two and cuts as soon as the difference reaches its threshold: 30 milliamps for those protecting people, within a few tens of milliseconds. Fast enough that an electric shock doesn't become electrocution.

The main switch near the meter cuts the whole house. It is often residual-current too, with a higher threshold and a slight delay, so that the 30 mA devices act first.

It tripped: read the message

An electrician's tips

Sources

French standard NF C 15-100, low-voltage electrical installations
Standard EN 60898-1, circuit breakers for household installations
Standards EN 61008 and 61009, residual current devices
Promotelec, electrical installation guides